A timeout occurred while waiting for an asynchronous receive event
Reinstall A3200 and its real-time operating system, INtime:
Uninstall A3200
Uninstall INtime (separate program from A3200)
Restart the PC
Reinstall A3200 (INtime is installed automatically)
Restart the PC
Pass the FireWire/HyperWIre card to INtime control.
Open INtime Configuration
Double click on INtime Device Manager.
Right click on the FireWire card and select Pass to INtime using Polling
Expand
title
Figure 1-1
For HyperWire cards, Pass to INtime using MSI
Expand
title
Figure 1-2
Navigate to File > Save Configuration. Exit INtime Device Manager and restart the PC.
The FireWire/HyperWire card could be defective. Replace the FireWire/HyperWire card.
Verify that your FireWire or HyperWire cables are working correctly. Test each cable separately. If necessary, replace the FireWire or HyperWire cable.
Optimize the PC. This can be done by following theOptimizing A3200 Performanceguide on our website. This includes a list of Windows and BIOS settings that are known to negatively affect real time performance which can cause communication issues.
The drive/controller hardware in the system could be defective. Replace the drive/controller.